| Type of radiation element |
HA1 |
200 |
300 |
400 |
500W |
| Power of radiation element |
HA2 |
400 |
600 |
800 |
1000W |
|
HA3 |
400 |
600 |
800 |
1000W |
|
| Maximum Power per m² radiation aera |
|
25.6 |
38.4 |
51.2 |
64㎾/㎡ |
| Wavelength range |
|
2~20㎛ |
| Max. permissible temperature |
|
720 |
760 |
820 |
860℃ |
| Typical
operating temperature if unimpeded radiation
is directed to the bottom vertically |
|
550 |
670 |
770 |
850℃ |
| Typical temperature of exposed goods |
|
220 |
260 |
290 |
310℃ |
| (guideline, since it strongly depends on the goods) |
|
|
|
|
| Heat-up
constant to 70% of the final temperature |
|
3.0 |
2.6 |
2.3 |
2.0min |
| Mean cool-down time from the final temperature to 200℃ |
|
7.4 |
9.4 |
9.6 |
10.5min |
| |
|
|
|
|
|
|
| The radiators
are optional available with integrated thermocouple |
|